DAYCO PRODUCTS INC
3100 MARICAMP RD., OCALA, FL, 34471
No open violations Compliance record — not a listed vendor
Facility identity · canonical
- EPA Registry ID
- 110000362642
- RCRA Handler ID(s)
- FLD096588520
- Generator status
- Small Quantity Generator (SQG)
- County
- MARION
- EPA Region
- 04
- Active
- Yes
- NAICS
- 326220
- Coordinates
- 29.162062, -82.095497
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
- Significant non-complier
- No
- Last inspection
- Nov 5, 2012
- Inspections (5 yr)
- —
- Informal actions (5 yr)
- —
- Formal actions (5 yr)
- —
- Total penalties
- —
Permits & authorizations · canonical
| Program | Type | Status | Effective |
|---|---|---|---|
| RCRA | SQG | Not reported | Not reported |
Type is EPA's RCRA handler classification. Permit status and effective date
are not published in the RCRAInfo handler dataset.
Violations · canonical · 12 total, 0 open
8 distinct violation categories on record:
| Count | Code | Category | EPA description |
|---|---|---|---|
| 2 | 262.A | Generator standards | Standards Applicable to Generators of HW: General |
| 2 | 265.B | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards |
| 2 | 265.C | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention |
| 2 | 273.B | Universal waste | Standards for Universal Waste Management: Standards for Small Quantity Handlers |
| 1 | 262.C | Generator standards | Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators |
| 1 | 265.D | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures |
| 1 | 279.C | Used oil management | Standards for Used Oil: Generators |
| 1 | XXS | State-specific requirement (broader than federal) | State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements |
Most recent 8 of 12:
| Determined | Category | Status | Agency |
|---|---|---|---|
| Aug 16, 2012 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Oct 31, 2012 | S |
| Aug 16, 2012 | Generator standards 262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators | Resolved Oct 31, 2012 | S |
| Aug 16, 2012 | TSDF standards (interim status) 265.B · Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards | Resolved Oct 4, 2012 | S |
| Aug 16, 2012 | TSDF standards (interim status) 265.B · Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards | Resolved Oct 23, 2012 | S |
| Aug 16, 2012 | TSDF standards (interim status) 265.C · Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention | Resolved Oct 5, 2012 | S |
| Aug 16, 2012 | TSDF standards (interim status) 265.C · Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention | Resolved Oct 18, 2012 | S |
| Aug 16, 2012 | TSDF standards (interim status) 265.D · Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures | Resolved Oct 22, 2012 | S |
| Aug 16, 2012 | Universal waste 273.B · Standards for Universal Waste Management: Standards for Small Quantity Handlers | Resolved Oct 5, 2012 | S |
Inspection history · canonical · 6 total
| Date | Type | Agency | Outcome |
|---|---|---|---|
| Nov 5, 2012 | NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) | S | In compliance |
| Sep 7, 2012 | SIGNIFICANT NON-COMPLIER (SNY) | S | Violation found |
| Aug 16, 2012 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
| May 15, 2003 | COMPLIANCE EVALUATION INSPECTION (CEI) | E | Violation found |
| May 15, 2003 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | In compliance |
| Mar 10, 1988 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | In compliance |
Related facilities near Ocala
Data sources
EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the
ECHO report linked above — RCRAInfo's own public search doesn't offer a stable
per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited.
Contact info and description come from the business's claimed listing, if any.
This profile is not an official regulatory determination.