UTICA CORP
8273 HALSEY RD., WHITESBORO, NY, 13492
No open violations Compliance record — not a listed vendor
Facility identity · canonical
- EPA Registry ID
- 110000325915
- RCRA Handler ID(s)
- NYD075814202
- Generator status
- Large Quantity Generator (LQG)
- County
- ONEIDA
- EPA Region
- 02
- Active
- Yes
- NAICS
- 333611336412331511
- Coordinates
- 43.107742, -75.338352
Compliance summary · canonical · as of Aug 26, 2026
3-year compliance history In violation 5 of the last 12 quarters
Not in universe In violation Significant non-compliance
- Significant non-complier
- No
- Last inspection
- Jun 12, 2024
- Inspections (5 yr)
- 1
- Informal actions (5 yr)
- 1
- Formal actions (5 yr)
- —
- Total penalties
- —
Permits & authorizations · canonical
| Program | Type | Status | Effective |
|---|---|---|---|
| RCRA | LQG | Not reported | Not reported |
Type is EPA's RCRA handler classification. Permit status and effective date
are not published in the RCRAInfo handler dataset.
Violations · canonical · 18 total, 0 open
8 distinct violation categories on record:
| Count | Code | Category | EPA description |
|---|---|---|---|
| 11 | 262.A | Generator standards | Standards Applicable to Generators of HW: General |
| 1 | 262.B | Generator standards | Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators |
| 1 | 262.C | Generator standards | Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators |
| 1 | 265.B | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards |
| 1 | 265.D | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures |
| 1 | 265.J | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Tank Systems |
| 1 | 268.A | Land disposal restrictions | Land Disposal Restrictions: General |
| 1 | XXS | State-specific requirement (broader than federal) | State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements |
Most recent 8 of 18:
| Determined | Category | Status | Agency |
|---|---|---|---|
| Jun 12, 2024 | TSDF standards (interim status) 265.D · Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures | Resolved Aug 14, 2024 | S |
| Sep 28, 2021 | TSDF standards (interim status) 265.J · Interim Status Standards for Owners and Operators of HW TSDs: Tank Systems | Resolved Jun 3, 2024 | S |
| Sep 8, 2015 | Generator standards 262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators | Resolved Nov 9, 2015 | S |
| Sep 8, 2015 | State-specific requirement (broader than federal) XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements | Resolved Nov 9, 2015 | S |
| Feb 28, 2012 | TSDF standards (interim status) 265.B · Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards | Resolved Feb 28, 2012 | S |
| Mar 15, 2004 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Jul 7, 2004 | E |
| Nov 16, 2001 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Nov 28, 2001 | S |
| Jan 21, 2000 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Jun 9, 2000 | S |
Inspection history · canonical · 18 total
| Date | Type | Agency | Outcome |
|---|---|---|---|
| Jun 12, 2024 | FOCUSED COMPLIANCE INSPECTION (FCI) | S | Violation found |
| Sep 28, 2021 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
| Jan 15, 2019 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | In compliance |
| Sep 8, 2015 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
| Feb 28, 2012 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
| Aug 30, 2007 | COMPLIANCE EVALUATION INSPECTION (CEI) | E | In compliance |
| Mar 15, 2004 | COMPLIANCE EVALUATION INSPECTION (CEI) | E | Violation found |
| Nov 16, 2001 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
Showing 8 most recent of 18.
Related facilities near Whitesboro
Data sources
EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the
ECHO report linked above — RCRAInfo's own public search doesn't offer a stable
per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited.
Contact info and description come from the business's claimed listing, if any.