TOKYO CLEANERS
426 E 2ND ST, LOS ANGELES, CA, 90012
No open violations Compliance record — not a listed vendor
Facility identity · canonical
- EPA Registry ID
- 110002728978
- RCRA Handler ID(s)
- CAC003009027, CAD981625619
- Generator status
- Small Quantity Generator (SQG)
- County
- LOS ANGELES
- EPA Region
- 09
- Active
- Yes
- NAICS
- 5629981232
- Coordinates
- 34.047345, -118.23882
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
- Significant non-complier
- No
- Last inspection
- May 15, 1995
- Inspections (5 yr)
- —
- Informal actions (5 yr)
- —
- Formal actions (5 yr)
- —
- Total penalties
- —
Permits & authorizations · canonical
| Program | Type | Status | Effective |
|---|---|---|---|
| RCRA | SQG | Not reported | Not reported |
Type is EPA's RCRA handler classification. Permit status and effective date
are not published in the RCRAInfo handler dataset.
Violations · canonical · 1 total, 0 open
All violations:
| Determined | Category | Status | Agency |
|---|---|---|---|
| Mar 8, 1993 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved May 15, 1995 | S |
Inspection history · canonical · 2 total
| Date | Type | Agency | Outcome |
|---|---|---|---|
| May 15, 1995 | COMPLIANCE EVALUATION INSPECTION (CEI) | B | In compliance |
| Mar 8, 1993 | COMPLIANCE EVALUATION INSPECTION (CEI) | B | Violation found |
Related facilities near Los Angeles
Data sources
EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the
ECHO report linked above — RCRAInfo's own public search doesn't offer a stable
per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited.
Contact info and description come from the business's claimed listing, if any.
This profile is not an official regulatory determination.