SAV-ON PLATING, INC.

15523 ILLINOIS AVE., PARAMOUNT, CA, 90723
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110000475986
RCRA Handler ID(s)
CAD990806523
Generator status
Large Quantity Generator (LQG)
County
LOS ANGELES
EPA Region
09
Active
Yes
NAICS
332813
332812
Coordinates
33.89213, -118.16542
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Jun 5, 2013
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA LQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 4 total, 0 open
2 distinct violation categories on record:
CountCodeCategoryEPA description
3 262.A Generator standards Standards Applicable to Generators of HW: General
1 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
All violations:
DeterminedCategoryStatusAgency
Apr 23, 2010
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved Jun 24, 2010 E
May 9, 2007
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved May 9, 2007 S
Apr 6, 1999
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jul 13, 1999 E
Nov 23, 1994
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Apr 6, 1999 S
Inspection history · canonical · 7 total
DateTypeAgencyOutcome
Jun 5, 2013 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
May 4, 2012 SIGNIFICANT NON-COMPLIER (SNY) S In compliance
Apr 23, 2010 COMPLIANCE EVALUATION INSPECTION (CEI) E Violation found
May 9, 2007 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Jul 13, 1999 COMPLIANCE EVALUATION INSPECTION (CEI) E In compliance
Apr 6, 1999 COMPLIANCE EVALUATION INSPECTION (CEI) E Violation found
Nov 23, 1994 COMPLIANCE EVALUATION INSPECTION (CEI) B Violation found

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.