ROBBINS MANUFACTURING CO

NEBRASKA & 131ST AVE, TAMPA, FL, 33612
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110040491802
RCRA Handler ID(s)
FLD004089231
Generator status
County
HILLS
EPA Region
04
Active
Yes
NAICS
321114
Coordinates
28.065661, -82.44983
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Mar 28, 2019
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
No permits on record.
Violations · canonical · 39 total, 0 open
10 distinct violation categories on record:
CountCodeCategoryEPA description
9 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
7 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
5 265.D TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
5 279.C Used oil management Standards for Used Oil: Generators
4 265.W TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Drip Pads
3 262.A Generator standards Standards Applicable to Generators of HW: General
2 265.B TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards
2 268.A Land disposal restrictions Land Disposal Restrictions: General
1 265.J TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Tank Systems
1 273.B Universal waste Standards for Universal Waste Management: Standards for Small Quantity Handlers
Most recent 8 of 39:
DeterminedCategoryStatusAgency
Mar 25, 2015
TSDF standards (interim status)
265.B · Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards
Resolved Jul 21, 2015 S
Mar 25, 2015
TSDF standards (interim status)
265.D · Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
Resolved Jul 21, 2015 S
Mar 25, 2015
TSDF standards (interim status)
265.W · Interim Status Standards for Owners and Operators of HW TSDs: Drip Pads
Resolved Jul 21, 2015 S
Mar 25, 2015
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Jul 21, 2015 S
Apr 13, 2011
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved May 24, 2011 S
Apr 13, 2011
TSDF standards (interim status)
265.D · Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
Resolved May 24, 2011 S
Apr 13, 2011
Universal waste
273.B · Standards for Universal Waste Management: Standards for Small Quantity Handlers
Resolved May 24, 2011 S
Dec 16, 2009
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved Mar 3, 2010 S
Inspection history · canonical · 16 total
DateTypeAgencyOutcome
Mar 28, 2019 COMPLIANCE EVALUATION INSPECTION (CEI) S In compliance
Mar 25, 2015 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Apr 13, 2011 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
May 4, 2010 COMPLIANCE EVALUATION INSPECTION (CEI) S In compliance
Dec 16, 2009 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Feb 28, 2007 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Jul 20, 2005 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Aug 6, 2001 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Showing 8 most recent of 16.

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.