NORTH FORT WORTH PLATING COMPANY

3105 HAYS, FORT WORTH, TX, 76106
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110005113073
RCRA Handler ID(s)
TXD982759490
Generator status
County
TARRANT
EPA Region
06
Active
NAICS
Coordinates
32.79999, -97.33876
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Jun 30, 2009
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
No permits on record.
Violations · canonical · 6 total, 0 open
2 distinct violation categories on record:
CountCodeCategoryEPA description
4 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
2 262.A Generator standards Standards Applicable to Generators of HW: General
All violations:
DeterminedCategoryStatusAgency
Jun 30, 2009
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved May 9, 2011 S
Jun 30, 2009
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved May 9, 2011 S
Mar 4, 2005
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved May 9, 2011 S
Mar 4, 2005
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved May 9, 2011 S
Mar 4, 2005
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved May 9, 2011 S
Mar 4, 2005
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved May 9, 2011 S
Inspection history · canonical · 3 total
DateTypeAgencyOutcome
Jun 30, 2009 COMPLIANCE SCHEDULE EVALUATION (CSE) S Violation found
Mar 22, 2007 COMPLIANCE SCHEDULE EVALUATION (CSE) S In compliance
Mar 4, 2005 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.