FLORIDA COLLISION & SERVICE CENTER

2625 N MAIN ST, GAINESVILLE, FL, 32609
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110032985624
RCRA Handler ID(s)
FLD118666130
Generator status
Very Small Quantity Generator (VSQG)
County
ALACHUA
EPA Region
04
Active
Yes
NAICS
811192
811121
Coordinates
29.676603, -82.319258
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Sep 8, 2011
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA CESQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 5 total, 0 open
4 distinct violation categories on record:
CountCodeCategoryEPA description
2 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
1 261.A RCRA 261.A ID and Listing of HW: General
1 262.A Generator standards Standards Applicable to Generators of HW: General
1 279.C Used oil management Standards for Used Oil: Generators
All violations:
DeterminedCategoryStatusAgency
Sep 8, 2011
RCRA 261.A
261.A · ID and Listing of HW: General
Resolved Jan 26, 2012 S
Sep 8, 2011
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jan 26, 2012 S
Sep 8, 2011
Used oil management
279.C · Standards for Used Oil: Generators
Resolved Sep 8, 2011 S
Sep 8, 2011
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Jan 26, 2012 S
Sep 8, 2011
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Sep 8, 2011 S
Inspection history · canonical · 1 total
DateTypeAgencyOutcome
Sep 8, 2011 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found