EUROFINS DRINKING WATER AND WASTEWATER SOUTHEAST LLC
481 NEWBURYPORT AVE, ALTAMONTE SPRINGS, FL, 32701
No open violations Compliance record — not a listed vendor
Facility identity · canonical
- EPA Registry ID
- 110005620113
- RCRA Handler ID(s)
- FLD984246447
- Generator status
- Small Quantity Generator (SQG)
- County
- SEMINOLE
- EPA Region
- 04
- Active
- Yes
- NAICS
- 541380
- Coordinates
- 28.669223, -81.359234
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
- Significant non-complier
- No
- Last inspection
- Apr 23, 2013
- Inspections (5 yr)
- —
- Informal actions (5 yr)
- —
- Formal actions (5 yr)
- —
- Total penalties
- —
Permits & authorizations · canonical
| Program | Type | Status | Effective |
|---|---|---|---|
| RCRA | SQG | Not reported | Not reported |
Type is EPA's RCRA handler classification. Permit status and effective date
are not published in the RCRAInfo handler dataset.
Violations · canonical · 12 total, 0 open
8 distinct violation categories on record:
| Count | Code | Category | EPA description |
|---|---|---|---|
| 3 | 262.A | Generator standards | Standards Applicable to Generators of HW: General |
| 2 | 261.A | RCRA 261.A | ID and Listing of HW: General |
| 2 | 279.C | Used oil management | Standards for Used Oil: Generators |
| 1 | 262.B | Generator standards | Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators |
| 1 | 262.C | Generator standards | Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators |
| 1 | 265.I | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Use and Management of Containers |
| 1 | 265.N | TSDF standards (interim status) | Interim Status Standards for Owners and Operators of HW TSDs: Landfills |
| 1 | XXS | State-specific requirement (broader than federal) | State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements |
Most recent 8 of 12:
| Determined | Category | Status | Agency |
|---|---|---|---|
| May 22, 2013 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Sep 4, 2013 | S |
| Apr 23, 2013 | RCRA 261.A 261.A · ID and Listing of HW: General | Resolved Sep 4, 2013 | S |
| Apr 23, 2013 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Sep 4, 2013 | E |
| Apr 23, 2013 | Used oil management 279.C · Standards for Used Oil: Generators | Resolved Sep 4, 2013 | E |
| Apr 23, 2013 | Used oil management 279.C · Standards for Used Oil: Generators | Resolved Sep 4, 2013 | S |
| Jan 9, 2003 | RCRA 261.A 261.A · ID and Listing of HW: General | Resolved Jun 6, 2003 | S |
| Jan 9, 2003 | Generator standards 262.A · Standards Applicable to Generators of HW: General | Resolved Jun 6, 2003 | S |
| Jan 9, 2003 | Generator standards 262.B · Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators | Resolved Jun 6, 2003 | S |
Inspection history · canonical · 5 total
| Date | Type | Agency | Outcome |
|---|---|---|---|
| Apr 23, 2013 | COMPLIANCE EVALUATION INSPECTION (CEI) | E | Violation found |
| Apr 23, 2013 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
| May 14, 2003 | COMPLIANCE EVALUATION INSPECTION (CEI) | X | In compliance |
| May 14, 2003 | COMPLIANCE SCHEDULE EVALUATION (CSE) | S | In compliance |
| Jan 9, 2003 | COMPLIANCE EVALUATION INSPECTION (CEI) | S | Violation found |
Related facilities near Altamonte Springs
Data sources
EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the
ECHO report linked above — RCRAInfo's own public search doesn't offer a stable
per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited.
Contact info and description come from the business's claimed listing, if any.
This profile is not an official regulatory determination.