ELT HARRIMAN LLC (FORMERLY NEPERA INC)

41 ARDEN HOUSE RD, HARRIMAN, NY, 10926
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110000603222
RCRA Handler ID(s)
NYD002014595
Generator status
Large Quantity Generator (LQG)
County
ORANGE
EPA Region
02
Active
Yes
NAICS
325192
325411
325194
32511
325199
Coordinates
41.308585, -74.142172
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Jun 23, 2005
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA LQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 22 total, 0 open
10 distinct violation categories on record:
CountCodeCategoryEPA description
8 264.A TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General
4 264.O TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Incinerators
2 268.A Land disposal restrictions Land Disposal Restrictions: General
2 270.B Permit requirements EPA Administered Permit Programs: the HW Permit Program Permit Application
1 262.A Generator standards Standards Applicable to Generators of HW: General
1 264.B TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General Facility Standards
1 264.E TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Manifest System, Recordkeeping and Reporting
1 264.H TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Financial Requirements
1 264.I TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Use and Management of Containers
1 264.J TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Tank Systems
Most recent 8 of 22:
DeterminedCategoryStatusAgency
Jun 23, 2005
TSDF standards (permitted)
264.H · Standards for Owners and Operators of HW TSDs: Financial Requirements
Resolved Sep 12, 2005 S
Mar 11, 2004
TSDF standards (permitted)
264.O · Standards for Owners and Operators of HW TSDs: Incinerators
Resolved Apr 13, 2004 S
Mar 11, 2004
TSDF standards (permitted)
264.O · Standards for Owners and Operators of HW TSDs: Incinerators
Resolved Apr 16, 2004 S
Sep 26, 2002
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved May 24, 2004 S
Sep 26, 2002
TSDF standards (permitted)
264.B · Standards for Owners and Operators of HW TSDs: General Facility Standards
Resolved May 24, 2004 S
Sep 26, 2002
TSDF standards (permitted)
264.I · Standards for Owners and Operators of HW TSDs: Use and Management of Containers
Resolved May 24, 2004 S
Sep 26, 2002
TSDF standards (permitted)
264.J · Standards for Owners and Operators of HW TSDs: Tank Systems
Resolved May 24, 2004 S
Sep 26, 2002
TSDF standards (permitted)
264.O · Standards for Owners and Operators of HW TSDs: Incinerators
Resolved May 24, 2004 S
Inspection history · canonical · 39 total
DateTypeAgencyOutcome
Jun 23, 2005 FINANCIAL RECORD REVIEW (FRR) S Violation found
Dec 3, 2004 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
Aug 18, 2004 SIGNIFICANT NON-COMPLIER (SNY) S In compliance
Mar 11, 2004 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
May 20, 2003 COMPLIANCE EVALUATION INSPECTION (CEI) E In compliance
Nov 21, 2002 SIGNIFICANT NON-COMPLIER (SNY) S In compliance
Sep 26, 2002 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Oct 30, 2001 COMPLIANCE EVALUATION INSPECTION (CEI) S In compliance
Showing 8 most recent of 39.

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.