DIAMONDBACK MANUFACTURING, LLC

1060 COX ROAD, COCOA, FL, 32926
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110058193137
RCRA Handler ID(s)
FLR000091579
Generator status
Small Quantity Generator (SQG)
County
BREVARD
EPA Region
04
Active
Yes
NAICS
336612
Coordinates
28.374169, -80.78854
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Dec 8, 2009
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA SQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 8 total, 0 open
6 distinct violation categories on record:
CountCodeCategoryEPA description
2 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
2 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
1 262.A Generator standards Standards Applicable to Generators of HW: General
1 265.N TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Landfills
1 279.C Used oil management Standards for Used Oil: Generators
1 PCR RCRA PCR Violation of a permit condition or requirement
All violations:
DeterminedCategoryStatusAgency
Aug 3, 2007
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved Oct 23, 2007 S
Aug 3, 2007
Used oil management
279.C · Standards for Used Oil: Generators
Resolved Oct 23, 2007 S
Aug 3, 2007
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Oct 23, 2007 S
Aug 4, 2005
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jul 14, 2006 S
Aug 4, 2005
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved Jul 14, 2006 S
Aug 4, 2005
TSDF standards (interim status)
265.N · Interim Status Standards for Owners and Operators of HW TSDs: Landfills
Resolved Jul 14, 2006 S
Aug 4, 2005
RCRA PCR
PCR · Violation of a permit condition or requirement
Resolved Jul 14, 2006 S
Aug 4, 2005
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Jul 14, 2006 S
Inspection history · canonical · 8 total
DateTypeAgencyOutcome
Dec 8, 2009 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
Jan 24, 2008 NON-FINANCIAL RECORD REVIEW (NRR) S In compliance
Aug 3, 2007 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Aug 3, 2007 SIGNIFICANT NON-COMPLIER (SNY) S In compliance
Aug 16, 2006 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
Mar 10, 2006 COMPLIANCE SCHEDULE EVALUATION (CSE) S In compliance
Aug 5, 2005 SIGNIFICANT NON-COMPLIER (SNY) S In compliance
Aug 4, 2005 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.