DHL SUPPLY CHAIN RN USA LLC

1821 S COUNTY LINE RD, PLANT CITY, FL, 33566
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110070511621
RCRA Handler ID(s)
FLR000229583
Generator status
Small Quantity Generator (SQG)
County
HILLSBOROUGH
EPA Region
04
Active
Yes
NAICS
Coordinates
27.996995, -82.055952
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history In violation 1, in significant non-compliance 3 of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Feb 18, 2026
Inspections (5 yr)
2
Informal actions (5 yr)
1
Formal actions (5 yr)
1
Total penalties
$66,081
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA SQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 6 total, 0 open
3 distinct violation categories on record:
CountCodeCategoryEPA description
3 262.A Generator standards Standards Applicable to Generators of HW: General
2 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
1 268.A Land disposal restrictions Land Disposal Restrictions: General
All violations:
DeterminedCategoryStatusAgency
Feb 18, 2026
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Mar 6, 2026 S
Jan 8, 2025
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Feb 26, 2025 S
Jan 8, 2025
Land disposal restrictions
268.A · Land Disposal Restrictions: General
Resolved Feb 26, 2025 S
Jan 8, 2025
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Feb 26, 2025 S
Mar 26, 2019
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Mar 29, 2019 S
Mar 26, 2019
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Mar 29, 2019 S
Inspection history · canonical · 5 total
DateTypeAgencyOutcome
Feb 18, 2026 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Jul 23, 2025 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S Violation found
Feb 3, 2025 SIGNIFICANT NON-COMPLIER (SNY) S Violation found
Jan 8, 2025 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Mar 26, 2019 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.