COATING TECHNOLOGY

800 ST PAUL ST MAIN FLOOR, ROCHESTER, NY, 14605
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110004540140
RCRA Handler ID(s)
NYR000049908
Generator status
Large Quantity Generator (LQG)
County
MONROE
EPA Region
02
Active
Yes
NAICS
332813
Coordinates
43.17068, -77.62052
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
May 2, 2023
Inspections (5 yr)
1
Informal actions (5 yr)
1
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA LQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 17 total, 0 open
10 distinct violation categories on record:
CountCodeCategoryEPA description
3 265.C TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
2 262.A Generator standards Standards Applicable to Generators of HW: General
2 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
2 265.B TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards
2 265.D TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
2 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
1 261.A RCRA 261.A ID and Listing of HW: General
1 262.B Generator standards Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators
1 265.I TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Use and Management of Containers
1 273.B Universal waste Standards for Universal Waste Management: Standards for Small Quantity Handlers
Most recent 8 of 17:
DeterminedCategoryStatusAgency
May 2, 2023
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved May 3, 2023 S
May 2, 2023
TSDF standards (interim status)
265.B · Interim Status Standards for Owners and Operators of HW TSDs: General Facility Standards
Resolved May 8, 2023 S
May 2, 2023
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved May 3, 2023 S
Dec 5, 2017
TSDF standards (interim status)
265.C · Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
Resolved Jan 22, 2018 S
Dec 5, 2017
Universal waste
273.B · Standards for Universal Waste Management: Standards for Small Quantity Handlers
Resolved Jan 22, 2018 S
Apr 10, 2014
TSDF standards (interim status)
265.C · Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
Resolved May 15, 2014 S
Aug 17, 2011
TSDF standards (interim status)
265.D · Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
Resolved Sep 23, 2011 S
Feb 25, 2010
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Mar 25, 2011 S
Inspection history · canonical · 9 total
DateTypeAgencyOutcome
May 2, 2023 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Dec 5, 2017 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Apr 10, 2014 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Sep 23, 2011 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
Aug 17, 2011 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Feb 26, 2010 SIGNIFICANT NON-COMPLIER (SNY) S Violation found
Feb 25, 2010 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Jul 7, 2003 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Showing 8 most recent of 9.

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.