CLEAN HARBORS ENVIRONMENTAL SERVICES

2900 ROCKFELLER AVE, CLEVELAND, OH, 44115
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110012536087
RCRA Handler ID(s)
OHD000724153
Generator status
Small Quantity Generator (SQG)
County
CUYAHOGA
EPA Region
05
Active
Yes
NAICS
562211 · Hazardous waste treatment & disposal
562212 · Solid waste landfill
Coordinates
41.48147, -81.67129
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history In violation 1 of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Apr 2, 2026
Inspections (5 yr)
2
Informal actions (5 yr)
2
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA SQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 21 total, 0 open
8 distinct violation categories on record:
CountCodeCategoryEPA description
12 262.A Generator standards Standards Applicable to Generators of HW: General
2 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
2 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
1 262.B Generator standards Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators
1 264.B TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General Facility Standards
1 265.E TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Manifest System, Recordkeeping and Reporting
1 268.A Land disposal restrictions Land Disposal Restrictions: General
1 279.C Used oil management Standards for Used Oil: Generators
Most recent 8 of 21:
DeterminedCategoryStatusAgency
Dec 12, 2025
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Dec 12, 2025 S
Jun 22, 2021
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Aug 24, 2021 S
Dec 11, 2013
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved May 21, 2014 E
Dec 11, 2013
Generator standards
262.B · Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators
Resolved May 21, 2014 E
Dec 11, 2013
Used oil management
279.C · Standards for Used Oil: Generators
Resolved May 21, 2014 E
Mar 12, 2009
TSDF standards (interim status)
265.E · Interim Status Standards for Owners and Operators of HW TSDs: Manifest System, Recordkeeping and Reporting
Resolved May 14, 2009 S
Oct 3, 2006
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Mar 10, 2008 S
Nov 12, 2002
TSDF standards (permitted)
264.B · Standards for Owners and Operators of HW TSDs: General Facility Standards
Resolved Jan 15, 2003 S
Inspection history · canonical · 41 total
DateTypeAgencyOutcome
Apr 2, 2026 COMPLIANCE EVALUATION INSPECTION (CEI) E Undetermined
Dec 12, 2025 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Jun 22, 2021 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Aug 24, 2018 FOCUSED COMPLIANCE INSPECTION (FCI) S Undetermined
Jul 28, 2016 COMPLIANCE EVALUATION INSPECTION (CEI) S In compliance
Dec 11, 2013 COMPLIANCE EVALUATION INSPECTION (CEI) E Violation found
Mar 12, 2009 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Mar 10, 2008 NO LONGER A SIGNIFICANT NON-COMPLIER (SNN) S In compliance
Showing 8 most recent of 41.

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.