CHEMTRON CORP

35850 SCHNEIDER RD, AVON, OH, 44011
EPA public record Significant non-complier
Part of CHEMTRON CORP — 3 EPA-regulated sites nationwide
Claim this listing

Is this your business? Add a description, contact info, and services.

Facility identity · canonical

EPA Registry ID
110000385137
RCRA Handler ID(s)
OHD066060609
Generator status
Large Quantity Generator (LQG)
County
LORAIN
EPA Region
05
Active
Yes
NAICS
562998 · All other misc. waste management
562920 · Materials recovery facilities
562211 · Hazardous waste treatment & disposal
56299
562112 · Hazardous waste collection
561990
Coordinates
41.47154, -82.01677
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history In violation 10, in significant non-compliance 1 of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
Yes
Last inspection
Apr 17, 2026
Inspections (5 yr)
5
Informal actions (5 yr)
6
Formal actions (5 yr)
4
Total penalties
$375,000
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA LQG Not reported Not reported
RCRA TSDF Not reported Not reported
RCRA Transporter Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 250 total, 6 open
34 distinct violation categories on record:
CountCodeCategoryEPA description
26 264.B TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General Facility Standards
24 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
22 264.E TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Manifest System, Recordkeeping and Reporting
19 262.A Generator standards Standards Applicable to Generators of HW: General
17 264.C TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
16 264.I TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Use and Management of Containers
15 270.C Permit requirements EPA Administered Permit Programs: the HW Permit Program Permit Conditions
13 264.H TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Financial Requirements
10 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
8 PCR RCRA PCR Violation of a permit condition or requirement
7 262.B Generator standards Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators
7 264.A TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General
7 270.B Permit requirements EPA Administered Permit Programs: the HW Permit Program Permit Application
6 264.D TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
6 268.A Land disposal restrictions Land Disposal Restrictions: General
6 268.E Land disposal restrictions Land Disposal Restrictions: Prohibitions on Storage
6 270.A Permit requirements EPA Administered Permit Programs: the HW Permit Program General Information
5 279.F Used oil management Standards for Used Oi:l Processors and Re-Refiners
4 262.D Generator standards Standards Applicable to Recordkeeping and Reporting Applicable to Small and Large Quantity Generators
4 264.J TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Tank Systems
3 264.BB TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Air Emission Standards for Equipment Leaks
3 264.G TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Closure and Post-Closure
2 264.F TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: Releases from Solid Waste Management Units
2 265.I TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Use and Management of Containers
2 273.C Universal waste Standards for Universal Waste Management: Standards for Large Quantity Handlers
2 279.E Used oil management Standards for Used Oil: Transporter and Transfer Facilities
1 262.M Generator standards Standards Applicable to Generators of HW: Preparedness. Prevention, and Emergency Procedures for LQGs
1 263.B Transporter standards Standards Applicable to Transporters of HW: Compliance with the Manifest System and Recordkeeping
1 265.C TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
1 265.D TSDF standards (interim status) Interim Status Standards for Owners and Operators of HW TSDs: Contingency Plan and Emergency Procedures
1 270.F Permit requirements EPA Administered Permit Programs: the HW Permit Program Special Forms of Permits
1 273.A Universal waste Standards for Universal Waste Management: General
1 273.B Universal waste Standards for Universal Waste Management: Standards for Small Quantity Handlers
1 279.A Used oil management Standards for the Management of Used Oil: Definitions
Most recent 8 of 250:
DeterminedCategoryStatusAgency
Jun 11, 2024
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jun 11, 2024 S
Jun 11, 2024
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jun 17, 2024 S
Jun 11, 2024
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Jun 19, 2024 S
Jun 11, 2024
Generator standards
262.A · Standards Applicable to Generators of HW: General
Open S
Jun 11, 2024
Generator standards
262.B · Standards Applicable to Generators of HW: Manifest Requirements Applicable to Small and Large Quantity Generators
Open S
Jun 11, 2024
Transporter standards
263.B · Standards Applicable to Transporters of HW: Compliance with the Manifest System and Recordkeeping
Open S
Jun 11, 2024
TSDF standards (permitted)
264.B · Standards for Owners and Operators of HW TSDs: General Facility Standards
Open S
Jun 11, 2024
TSDF standards (permitted)
264.C · Standards for Owners and Operators of HW TSDs: Preparedness and Prevention
Resolved Jun 13, 2024 S
Inspection history · canonical · 174 total
DateTypeAgencyOutcome
Apr 17, 2026 NON-FINANCIAL RECORD REVIEW (NRR) S In compliance
Oct 21, 2025 FOCUSED COMPLIANCE INSPECTION (FCI) S Undetermined
Sep 29, 2025 FINANCIAL RECORD REVIEW (FRR) S Undetermined
Aug 13, 2025 FOCUSED COMPLIANCE INSPECTION (FCI) S In compliance
Jul 9, 2025 NON-FINANCIAL RECORD REVIEW (NRR) S In compliance
Jun 24, 2025 COMPLIANCE EVALUATION INSPECTION (CEI) S Undetermined
Sep 25, 2024 FINANCIAL RECORD REVIEW (FRR) S Undetermined
Jun 11, 2024 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found
Showing 8 most recent of 174.

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.