BEST TRUCK REPAIR INC

10653 W OKEECHOBEE RD, HIALEAH GARDENS, FL, 33018
No open violations Compliance record — not a listed vendor
Compliance record, not a business listing. This facility is a hazardous-waste generator (it produces regulated waste as part of an unrelated business), not a waste-management vendor — it isn't eligible to be claimed or listed. Data below is shown for compliance transparency, sourced from EPA ECHO & RCRAInfo.

Facility identity · canonical

EPA Registry ID
110005594197
RCRA Handler ID(s)
FLD984171082
Generator status
Small Quantity Generator (SQG)
County
MIAMI-DADE
EPA Region
04
Active
Yes
NAICS
811198
Coordinates
25.87027, -80.342714
Compliance summary · canonical · as of Aug 11, 2026
3-year compliance history Not in the compliance universe for any of the last 12 quarters
Not in universe In violation Significant non-compliance
Significant non-complier
No
Last inspection
Oct 24, 2007
Inspections (5 yr)
Informal actions (5 yr)
Formal actions (5 yr)
Total penalties
Permits & authorizations · canonical
ProgramTypeStatusEffective
RCRA SQG Not reported Not reported
Type is EPA's RCRA handler classification. Permit status and effective date are not published in the RCRAInfo handler dataset.
Violations · canonical · 6 total, 0 open
6 distinct violation categories on record:
CountCodeCategoryEPA description
1 262.A Generator standards Standards Applicable to Generators of HW: General
1 262.C Generator standards Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
1 262.D Generator standards Standards Applicable to Recordkeeping and Reporting Applicable to Small and Large Quantity Generators
1 264.B TSDF standards (permitted) Standards for Owners and Operators of HW TSDs: General Facility Standards
1 279.C Used oil management Standards for Used Oil: Generators
1 XXS State-specific requirement (broader than federal) State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
All violations:
DeterminedCategoryStatusAgency
Oct 24, 2007
Generator standards
262.A · Standards Applicable to Generators of HW: General
Resolved Nov 8, 2007 S
Oct 24, 2007
Generator standards
262.C · Standards Applicable to Generators of HW: Pre-Transport Requirements Applicable to Small and Large Quantity Generators
Resolved Nov 8, 2007 S
Oct 24, 2007
Generator standards
262.D · Standards Applicable to Recordkeeping and Reporting Applicable to Small and Large Quantity Generators
Resolved Nov 8, 2007 S
Oct 24, 2007
TSDF standards (permitted)
264.B · Standards for Owners and Operators of HW TSDs: General Facility Standards
Resolved Nov 8, 2007 S
Oct 24, 2007
Used oil management
279.C · Standards for Used Oil: Generators
Resolved Nov 8, 2007 S
Oct 24, 2007
State-specific requirement (broader than federal)
XXS · State Statutory or Regulatory requirements that are broader-in-scope than the federal RCRA requirements
Resolved Nov 8, 2007 S
Inspection history · canonical · 1 total
DateTypeAgencyOutcome
Oct 24, 2007 COMPLIANCE EVALUATION INSPECTION (CEI) S Violation found

Data sources

EPA ECHO — this facility's detailed report — facility, compliance summary, permits, evaluations & violations
RCRAInfo evaluation and violation records for this facility are integrated into the ECHO report linked above — RCRAInfo's own public search doesn't offer a stable per-facility link. General source: EPA ECHO, EPA RCRAInfo.
Compliance, permit, and location data come straight from EPA and can't be edited. Contact info and description come from the business's claimed listing, if any. This profile is not an official regulatory determination.